About this product
CX3 power contactors are offered in 16 A, 25 A, 40 A and 63 A ratings with 1 to 3 module widths. Coil voltages are 24 V AC and 230 V AC (and 230 V AC low-noise for 16/25 A). Conditional short-circuit current is 6 kA for 16-25 A and 3 kA for 40-63 A when protected by a circuit breaker or gG fuse not exceeding the contactor rating. Spacing modules are recommended between contactors to manage heating.
Key features
- Conform to IEC/EN 61095
- Space for power supply busbar on top (up to 63 A)
- Ratings 16, 25, 40 and 63 A
- 1, 2 and 3 module widths
- Low-noise 230 V AC coil option on 16/25 A units
- Rated impulse withstand voltage 4 kV
- mechanical endurance 10^6 cycles
- Selection charts for lamp loads (incandescent, halogen, fluorescent, compact fluorescent, discharge lamps)
Applications
- Switching of lighting, heating and other loads from DIN-rail distribution boards
- Switching of lighting and power loads (lamp selection charts printed in brochure)
Specifications
Standard: IEC/EN 61095 | Rating Range: 25 A to 63 A | Rated Impulse Withstand Voltage (Uimp): 4 kV | Mechanical Endurance: 10^6 operating cycles | Operating Temperature: -25 °C to +40 °C | Storage Temperature: -40 °C to +70 °C | Short-Circuit Protection Standard: EN 61095 (Iq = 6 kA for 16-25 A; Iq = 3 kA for 40-63 A) | Coil Voltage - 16 A and 25 A: 24 V AC; 230 V AC; 230 V AC low noise | Coil Voltage - 40 A and 63 A: 24 V AC; 230 V AC | Contact Types Listed - 16 A and 25 A: 2 NO, 4 NO, 2 NC, 4 NC, NC + NO, 2 NC + 2 NO | Contact Types Listed - 40 A and 63 A: 2 NO, 3 NO, 4 NO, 2 NC, 4 NC | Dimensions - 16 A and 25 A: 1 module and 2 modules | Dimensions - 40 A and 63 A: 2 modules and 3 modules | Coil Holding Current - 16 A and 25 A (printed column order): 200 mA; 300 mA; 12 mA; 20 mA; 20 mA | Coil Inrush Current - 16 A and 25 A (printed column order): 970 mA; 2500 mA; 60 mA; 90 mA; 200 mA | Coil Holding Current - 40 A and 63 A (printed column order): 250 mA; 270 mA; 15 mA; 30 mA | Coil Inrush Current - 40 A and 63 A (printed column order): 1750 mA; 1500 mA; 150 mA; 200 mA | Max Connection Cross-Section - Rigid / Flexible (ratings ≤ 25 A): 6 mm² or 2 x 2.5 mm² | Max Connection Cross-Section - Rigid / Flexible (40 and 63 A): 25 mm² or 2 x 10 mm² | Max Connection Cross-Section - Flexible with Single End Cap: 6 mm² (≤ 25 A); 16 mm² (40 and 63 A) | Max Connection Cross-Section - Flexible with Double End Cap: 2 x 4 mm² (≤ 25 A); 2 x 16 mm² (40 and 63 A) | Spacing Recommendation: Insert a spacing module (Cat.No 4063 07) every two contactors below 40 °C ambient; every contactor between 40 and 60 °C | Dimensions p75 (A / B width / C / D / E / F, mm): 20 A: 62 / 17.8 / 60 / 83 / 44 / 67.5; 40 A (2 mod.): 60 / 35.6 / 61 / 80 / 44 / 67; 40 A / 63 A (3 mod.): 60 / 54 / 61 / 80 / 44 / 67
Standards: IEC/EN 61095 | EN 61095
Packing: Pack of 1