DX3 Type AC compact RCBO (2-module double pole and 4-module four pole) to NFC 61-410 / EN 61009-1; 2-pole 6-32 A, 4-pole 10-32 A, 30/300 mA. RCBOs provide fault current detection, measurement and cut-off, protection against overloads and short-circuits, and isolation of an installation.

Key features

  • Compact 2-module (DP) and 4-module (FP) construction
  • Rated sensitivity 30 or 300 mA
  • Blue indicator in front face window on earth-leakage trip
  • Test button for monthly testing

Applications

  • Combined earth-leakage, overload and short-circuit protection of final circuits

Specifications

Type: AC - 2 & 4 modules | Number of Modules: DP 2; FP 4 | Nominal Rating In - Double Pole: 6, 10, 16, 20, 25, 32 A | Nominal Rating In - Four Pole: 10, 16, 20, 25, 32 A | Rated Sensitivity: 30, 300 mA | Rated Frequency: 50 Hz | Rated Operating Voltage Ue - Double Pole: 230 V AC | Rated Operating Voltage Ue - Four Pole: 415 V AC | Minimum Operating Voltage: 12 V AC | Rated Insulation Voltage Ui - Double Pole: 250 V AC | Rated Insulation Voltage Ui - Four Pole: 500 V AC | Rated Impulse Withstand Voltage Uimp: 6 kV | Breaking Capacity: As per IS 12640 (Part 2):2008, IEC 61009-1 | Rated Making & Breaking Capacity (Im) - Up to 40 A: 6000 A | Rated Making & Breaking Capacity (Im) - 63 A and above: - | Rated Residual Making & Breaking Capacity (I∆m) - Up to 40 A: 3000 A | Rated Residual Making & Breaking Capacity (I∆m) - 63 A and above: - | Rated Service Short Circuit Capacity (Ics): 6000 A | Rated Short Circuit Capacity (Icn): 6000 A | Operating Temperature: -25 °C to +70 °C | Endurance - Mechanical: 20,000 cycles | Endurance - On Load: 10,000 cycles | Endurance - Via Test Button: 1,000 cycles | Endurance - By Fault Current (sensitivity): 1,000 cycles | Testing: Press test button; black dolly goes to OFF position; test once a month recommended | Fault Indication (earth leakage): Black dolly goes to OFF position and blue indicator appears in front face window | Fault Indication (overload and short circuit): Black dolly goes to OFF position | Resetting: Switch on black dolly | Terminals - Rigid: 0.75 - 16 sq mm | Terminals - Flexible: 0.75 - 10 sq mm | Type of Protection: Earth leakage, overload and short circuit | Add-on Electrical Accessories: Auxiliary, fault signalling, shunt trip, under voltage, over voltage

Standards: NFC 61-410 | EN 61009-1

Request a Quote

Get bulk pricing directly from the supplier.

Login to Request Quote
WHY BUY HERE
GST verified supplier
PAN & GSTIN checked by BrickoMart
Site delivery available
Coordinated with the supplier
GST invoice on every order
Full input tax credit
Quality-checked dispatch
Sourced from verified suppliers

More like this

Comparable products from verified suppliers

SITE Set delivery location
Home