Skip to main content

About this product

Li2Y(St)CYv (TP) is the Yv type of Li2Y(St)CY (TP), with a reinforced black outer sheath suitable for outdoor application; an armoured version for underground burial is available on request. Construction is PE-insulated cores in twisted pairs, aluminium backed PETP foil over the laid-up pairs and a tinned copper braided screen (approx. 85% coverage). It is used for interference-free data and signal transmission over longer distances, including RS 422 / RS 485 interfaces and SCADA systems.

Key features

  • Reinforced black outer sheath suitable for outdoor application
  • Armoured version for underground burial available on request
  • PE core insulation, twisted pairs with aluminium backed PETP foil and tinned copper braid
  • Suitable for RS 422 and RS 485 interfaces
  • Self-extinguishing, flame retardant to EN 60332-1-2

Applications

  • Interference-free transmission of data and signals over longer distances
  • RS 422 and RS 485 interfaces
  • Supervisory control and data acquisition (SCADA) systems
  • Fixed installation and flexing applications with free movement without forced motion and without tensile stress, in dry and moist environments
  • Outdoor installation (reinforced black sheath)

Specifications

Standard: Based on VDE 0812 | Voltage Grade (not for power installation): Max. 250 V | Test Voltage: Core/core 2000 V; Core/screen 1000 V | Insulation Resistance (min.): 5000 GΩ x cm | Mutual Capacitance (max.): 60 nF/km (applicable up to 0.5 sq mm) | Characteristic Impedance: 100 Ω ±15 (applicable up to 0.5 sq mm) | Cross-talk Attenuation: Up to 1 MHz min. 50 dB; up to 10 MHz min. 40 dB | Inductance (approx.): 0.65 mH/km | Temperature Range - Flexing: -5°C to +70°C | Temperature Range - Fixed Installation: -30°C to +70°C | Minimum Bending Radius - Flexing: 15 x cable ø | Minimum Bending Radius - Fixed Installation: 6 x cable ø | Conductor: Bare copper stranded 7-wire conductor (metal coated copper also offered on request) | Conductor Make-up: 0.22 sq mm = 7 x 0.20 mm; 0.34 sq mm = 7 x 0.25 mm; 0.5 sq mm = 7 x 0.30 mm | Conductor Resistance (loop) at 20°C: 0.22 sq mm = 186 Ω/km (max.); 0.34 sq mm = 115 Ω/km (max.); 0.5 sq mm = 78.5 Ω/km (max.) | Core Insulation: PE (polyethylene) | Core Colours: As per DIN 47100 (table no. 2-1) | Core Lay-up: Cores stranded in pairs and pairs stranded in layers with optimal lay-length; aluminium backed PETP foil over the laid-up pairs | Screen: Tinned copper braided screen, approx. 85% coverage | Outer Sheath: Special PVC TM2 (EN 50363-4.1) | Flame Retardancy: PVC self-extinguishing and flame retardant, EN 60332-1-2 | Sheath: Reinforced black outer sheath, suitable for outdoor application | Cross-section Range (listed in table): 0.22, 0.34, 0.5, 0.75, 1 sq mm | No. of Pairs Range (listed in table): 2 to 10

Standards: VDE 0812 | EN 50363-4.1 | DIN 47100 | EN 60332-1-2 | REACH | RoHS | CE

Request a Quote

Get bulk pricing directly from the supplier.

Login to Request Quote
WHY BUY HERE
GST verified supplier
PAN & GSTIN checked by BrickoMart
Site delivery available
Coordinated with the supplier
GST invoice on every order
Full input tax credit
Quality-checked dispatch
Sourced from verified suppliers

More like this

Comparable products from verified suppliers

SITE Set delivery location