Skip to main content

About this product

RATNALAN CAT 5e UTP is a high performance LAN cable used for modern computer network systems; such cables form the back bone of modern data transmission in industries, residential and commercial infrastructure. The brochure states that RATNALAN CAT 5e UTP is independently verified to exceed the requirements of EN 50173, ISO/IEC 11801 and TIA/EIA 568-B-1/B-2. Conductors are solid bare copper with high density polyethylene insulation, twisted in pairs, with an FR PVC outer jacket. Supplied in easy pull boxes of 101 m or 305 m.

Key features

  • Solid bare copper conductor with high density polyethylene insulation and FR PVC outer jacket
  • Four colour-coded twisted pairs (white-orange/orange, white-green/green, white-blue/blue, white-brown/brown)
  • REACH and RoHS compliant
  • Independently verified to exceed EN 50173, ISO/IEC 11801 and TIA/EIA 568-B-1/B-2
  • Easy pull box of 101 m or 305 m

Applications

  • Computer network systems (LAN) in industries, residential and commercial infrastructure

Specifications

Category: CAT 5e UTP | Conductor: Solid bare copper | Insulation: High density polyethylene | Pair: 2 insulated conductors twisted together | Outer Jacket: FR PVC | Pair Colour Code: 1 Pair: White-orange stripe and orange; 2 Pair: White-green stripe and green; 3 Pair: White-blue stripe and blue; 4 Pair: White-brown stripe and brown | Max. Tensile Load: 10 kg per simplex cable (installation) | Min. Bend Radius: 8 x outer diameter (installation); 4 x outer diameter (operation) | Temperature - Installation: 0°C to +50°C | Temperature - Operation: -10°C to +60°C | Applicable International Standards for Cable Construction: ISO/IEC 11801:2002; ISO/IEC 61156-5; EN 50173-1:2002; EN 50288-3-1; ANSI/TIA/EIA 568B-2:2002 | Electrical Characteristics at 20°C - Conductor Loop Resistance: 160/100m (specification: Max. 190/100m) | Electrical Characteristics at 20°C - Conductor Resistance Unbalance: 0.5% (specification: Max. 2%) | Electrical Characteristics at 20°C - Dielectric Strength: 100% in process test (specification: 1.0 kV DC or 0.7 kV AC for 1 min.) | Electrical Characteristics at 20°C - Insulation Resistance: >500 M-ohm/km (specification: >500 M-ohm/km at 100-500 V test voltage) | Electrical Characteristics at 20°C - Capacitance Unbalance to Earth: 40 pF/100m (specification: Max. 160 pF/100m) | Electrical Characteristics at 20°C - Velocity of Propagation: 496 nsec/100m at 100 MHz (NVP for hand held testers = 0.69) (specification: <534 nsec/100m at 100 MHz) | Electrical Characteristics at 20°C - Skew: Max. 25 nsec/100m at 100 MHz (specification: Max. 40 nsec/100m at 100 MHz) | Electrical Characteristics at 20°C - Mean Characteristic Impedance: 1000 +/- 30 at 100 MHz (as printed) (specification: 1000 +/- 50 at 100 MHz (as printed)) | Electrical Characteristics at 20°C - Coupling Attenuation up to 1 GHz: 50 dB (specification: Min. 40 dB) | Typical Headroom - Frequency (MHz): 1, 4, 10, 16, 20, 31.25, 62.5, 100, 155, 200, 300 | Typical Headroom - Insertion Loss (dB/100m) - Spec value: 2.0, 4.1, 6.5, 8.2, 9.3, 11.7, 17.0, 22.0, N/A, N/A, N/A | Typical Headroom - Insertion Loss (dB/100m) - Typical value: 1.8, 3.6, 5.8, 7.4, 8.3, 10.5, 15.3, 19.8, 25.4, 29.4, 33.4 | Typical Headroom - NEXT (dB) - Spec value: 65.3, 56.3, 50.3, 47.3, 45.8, 42.9, 38.4, 35.4, N/A, N/A, N/A | Typical Headroom - NEXT (dB) - Typical value: 73.3, 64.3, 58.3, 55.2, 53.8, 50.9, 46.4, 43.3, 40.4, 38.8, 37.3 | Typical Headroom - PSNEXT (dB) - Spec value: 62.3, 53.3, 47.3, 44.2, 42.8, 39.9, 35.4, 32.3, N/A, N/A, N/A | Typical Headroom - PSNEXT (dB) - Typical value: 71.3, 62.3, 56.3, 53.2, 51.8, 48.9, 44.4, 41.3, 38.4, 36.8, 35.3 | Typical Headroom - ELFEXT (dB/100m) - Spec value: 63.8, 51.8, 43.8, 39.7, 37.8, 33.9, 27.9, 23.8, N/A, N/A, N/A | Typical Headroom - ELFEXT (dB/100m) - Typical value: 78.8, 66.8, 58.8, 54.7, 52.8, 48.9, 42.9, 38.4, 35, 32.8, 31.5 | Typical Headroom - PSELFEXT (dB/100m) - Spec value: 60.8, 48.8, 40.8, 36.7, 34.8, 30.9, 24.9, 20.8, N/A, N/A, N/A | Typical Headroom - PSELFEXT (dB/100m) - Typical value: 76.8, 64.8, 56.8, 52.7, 50.8, 46.9, 40.9, 36.8, 33, 30.8, 29.5 | Typical Headroom - Return Loss (dB/100m) - Spec value: N/A, 23.1, 25.0, 25.0, 25.0, 23.6, 21.5, 20.1, N/A, N/A, N/A | Typical Headroom - Return Loss (dB/100m) - Typical value: 25.0, 28.0, 30.0, 30.0, 30.0, 38.6, 26.5, 25.1, 23.8, 23.0, 22.8 | Typical Headroom - ACR (dB/100m) - Typical value: 71.5, 60.7, 52.5, 47.8, 45.5, 40.4, 31.1, 23.5, 15.0, 9.4, 3.1 | Typical Headroom - PSACR (dB/100m) - Typical value: 69.5, 58.7, 50.5, 45.8, 43.5, 38.4, 29.1, 21.5, 13.0, 7.4, 2.0

Standards: EN 50173 | ISO/IEC 11801 | ISO/IEC 61156-5 | EN 50288-3-1 | ANSI/TIA/EIA 568B-2 | REACH | RoHS

Packing: Easy pull box of 101 m or 305 m

Request a Quote

Get bulk pricing directly from the supplier.

Login to Request Quote
WHY BUY HERE
GST verified supplier
PAN & GSTIN checked by BrickoMart
Site delivery available
Coordinated with the supplier
GST invoice on every order
Full input tax credit
Quality-checked dispatch
Sourced from verified suppliers

More like this

Comparable products from verified suppliers

SITE Set delivery location
Home