Skip to main content

About this product

Tri rated single-core cable with stranded copper conductor to BS EN 60228 cl. 5 and heat and damp resistant PVC core insulation to UL 1581 Class 43 and CSA C22.2 No. 210 ULVW-1 / CSA FT-1. It is rated UL AWM 105 deg C 600 V, CSA AWM 105 deg C 600 V and BS 6231 CK type 90 deg C 600/1000 V, and is REACH, RoHS, CE and CPR compliant. The PVC is self-extinguishing and flame retardant (UL VW-1, CSA FT 1 / FT 2, EN 60332-1-2) and conditionally resistant to oils, solvents, acids and dye. Insulation colour is selected through the 'xx' suffix in the part number.

Key features

  • Tri rated: UL AWM 105 deg C 600 V, CSA AWM 105 deg C 600 V and BS 6231 CK 90 deg C 600/1000 V
  • Sizes 1 x 0.5 to 1 x 240 sq mm (AWG 21 to 450 kcmil)
  • PVC self-extinguishing and flame retardant (UL VW-1, CSA FT 1 / FT 2, EN 60332-1-2)
  • Conditionally resistant to oils, solvents, acids and dye
  • Flexing -5 deg C to +105 deg C
  • fixed installation -20 deg C to +105 deg C
  • REACH, RoHS, CE and CPR compliant
  • 13 insulation colours selectable via part number suffix (xx)

Applications

  • Internal wiring of panels and electrical equipment
  • Connection wire in machines laid in protective tubes and flexible pipes
  • Motors and transformers

Specifications

Number of Cores: 1 | Nominal Voltage: 600 V | Conductor: Stranded copper conductor according to BS EN 60228, cl. 5 | Insulation: PVC core insulation according to UL Standard 1581 Class 43 and CSA C22.2 No. 210 ULVW-1 and CSA FT-1, heat and damp resistant | UL Rating: UL - Type AWM 105 deg C 600 V | CSA Rating: CSA - Type AWM 105 deg C 600 V | BS Rating: BS 6231 CK type 90 deg C 600 V / 1000 V | Test Voltage (Spark Test): AWG 18 to 16: 6 kV; AWG 8 and above: 7.5 kV | Temperature Range: Flexing -5 deg C to +105 deg C; fixed installation -20 deg C to +105 deg C | Bending Radius: Cable diameter up to 8 mm: 4 x outer diameter; approx. diameter above 8 to 12 mm: 5 x outer diameter; above 12 mm: 6 x outer diameter | Flame Retardance: PVC self-extinguishing, test method UL VW-1 and CSA FT 1 / FT 2; flame retardant to EN 60332-1-2 | Chemical Resistance: Conditionally resistant to oils, solvents, acids, dye | Current Ratings and Voltage Drop: Refer table no. 8-1 (as printed) | Size Range: 1 x 0.5 to 1 x 240 sq mm (AWG 21 to 450 kcmil) | Colour Code Suffix (xx in part number): 01 - green, 02 - black, 03 - red, 04 - blue, 05 - yellow, 06 - green/yellow, 07 - white, 08 - violet, 09 - brown, 10 - orange, 11 - pink, 12 - grey, 13 - light blue

Standards: UL 1015 | UL 758 | CSA C 22.2 No 210 | BS 6231 | UL 1581 | BS EN 60228 | EN 60332-1-2 | REACH | RoHS | CE | CPR

Request a Quote

Get bulk pricing directly from the supplier.

Login to Request Quote
WHY BUY HERE
GST verified supplier
PAN & GSTIN checked by BrickoMart
Site delivery available
Coordinated with the supplier
GST invoice on every order
Full input tax credit
Quality-checked dispatch
Sourced from verified suppliers

More like this

Comparable products from verified suppliers

SITE Set delivery location
Home