About this product
XLPE insulated appliance wiring material to UL Std. 758, complying with CSA No. 22.2 210 and 127, with annealed plain or tinned stranded copper conductor and XLPE insulation according to UL Std. 1581 Table 50.232. It has excellent resistance to abrasion, deformation, cut-through and chemical attack and is rated 600 V, flexible -5 deg C to +150 deg C. It can be used as Appliance Wiring Material (AWM), coil leads and as Class B IEEE 130 deg C Class motor leads, and is an economical replacement for silicone rubber / glass braid insulated wire and cable. The part number carries two selections: insulation colour (xx) and conductor type (c: annealed bare or annealed tinned copper).
Key features
- Covers UL styles 3289, 3321, 3173, 3271 and 3344
- Excellent resistance to abrasion, deformation, cut-through and chemical attack
- Nominal voltage 600 V
- temperature range flexible -5 deg C to +150 deg C, fixed installation -50 deg C to +150 deg C
- Annealed bare copper (ABC) or annealed tinned copper (ATC) conductor selectable via part number suffix (c)
- Sizes AWG 21 to 4/0 (0.5 to 120 sq mm)
- Economical replacement for silicone rubber / glass braid insulated wire and cable
- 13 insulation colours selectable via part number suffix (xx)
Applications
- Appliances
- Transformers
- Electrical heating
- Motors
- Ballast, lighting and cooking equipment
- Appliance Wiring Material (AWM) and coil leads
- Class B IEEE 130 deg C Class motor leads
Specifications
Number of Cores: 1 | Nominal Voltage: 600 V | Conductor: Annealed plain or tinned stranded copper conductor (tin plated copper conductor) | Insulation: XLPE insulation according to UL Std. 1581 Table 50.232, complies to CSA No. 22.2 210 and 127 | Test Voltage (Spark Test): AWG 22 and 20: 5 kV; AWG 18 to 10: 6 kV; AWG 8 and above: 7.5 kV | Temperature Range: Flexible -5 deg C to +150 deg C; fixed installation -50 deg C to +150 deg C | Max. Temperature at Conductor: +150 deg C (UL) | Bending Radius: Approx. 5 x cable diameter | Flame Retardance: PVC self-extinguishing and flame retardant, test method to FT 2 (as printed) | UL Styles Covered: 3289, 3321, 3173, 3271, 3344 | Size Range: AWG 21 to 4/0 (0.5 to 120 sq mm) | Colour Code Suffix (xx in part number): 01 - green, 02 - black, 03 - red, 04 - blue, 05 - yellow, 06 - green/yellow, 07 - white, 08 - violet, 09 - brown, 10 - orange, 11 - pink, 12 - grey, 13 - light blue | Conductor Type Suffix (c in part number): 0 = annealed bare copper (ABC), 1 = annealed tinned copper (ATC)
Standards: UL 758 | UL 3289 | UL 3321 | UL 3173 | UL 3271 | UL 3344 | UL 1581 | CSA 22.2 No. 210 | CSA 22.2 No. 127 | REACH | RoHS | CE